Hegwein was established in 1948, and is since 1996 member of the DURAG GROUP. More info about DURAG GROUP you can find here.
Hegwein develops and designs combustion equipment. Hegwein manufactures series e.i. produced components for OEMs in the combustion business and bespoke igniters, burners and pilot burners.
Why choosing Hegwein products ?
Compact, integrated design offers striking advantages
| Scope of supply | |
![]() ![]() ![]() ![]()
|
Gas fired igniters, pilot burners Oil fired igniters Dual fuel igniters Gas burners |
|
Gas fired igniters | |||||||||
| Heat release [ kW ] | 2 | 4 | 45 | 120 | 250 | 600 | 1000 | 2000 | 4000 |
| Max. flame length [ mm ] | 80 | 100 | 500 | 600 | 1200 | 2000 | 2000 | 2500 | 3000 |
| Outer tube diameter [ mm ] | 15 | 25 | 35 | 48/50 | 65/70 | 90 | 135 | 160 | 220 |
| No integrated electrical components | ZGF | ZGU | ZGP | ZG0 | ZG1 | ZG2 | ZG3 | ZG4 | ZG5 |
| With integrated spark transformer 110 - 125 V, 220 - 230 V, 240 - 250 V 50/60 Hz |
ZTF | ZTU | ZTP | ZT0 | ZT1 | ZT2 | ZT3 | ZT4 | ZT5 |
| With integrated spark transformer and ionisation flame monitor for intermittent operation (series ZA...) or continuous operation (series ZDA...) 115 V, 125 V, 230 V, 250 V 50/60 Hz |
ZAF ZDAF |
ZAU ZDAU |
ZAP ZDAP |
ZA0 ZDA0 |
ZA1 ZDA1 |
ZA2 ZDA2 |
ZA3 ZDA3 |
ZA4 ZDA4 |
ZA5 ZDA5 |
| With integrated spark transformer and burner control for intermittent operation (series ZR...) or continuous operation (series ZD...) 115 V, 125 V, 230 V, 250 V 50/60 Hz, IP 54 |
ZR1 ZD1 |
ZR2 ZD2 |
ZR3 ZD3 |
ZR4 ZD4 |
ZR5 ZD5 |
||||
| Special versions with integrated spark transformer and ionisation flame monitor | |||||||||
| Power head, for zone 1 or zone 21 | ZAVEX/F | ZAVEX/U | ZAVEX/P | ZAVEX/0 | ZAVEX | ZAVEX/2 | |||
| Power head, for zone 2 or zone 22 | ZXDAF | ZXDAU | ZXDAP | ZXDA0 | ZXDA1 | ZXDA2 | ZXDA3 | ZXDA4 | |
| Self aspirated igniter p > 1 barg | ZANP | ZAN0 | ZAN1 | ||||||
|
Oil fired igniters & dual fuel igniters | |||||||
| Type | ZAEL0 | ZAEL1 | ZAEL2 | ZAEL3 | ZAEL4 | ZAZL2 | ZAZL3 |
| Max. heat release, oil mode [ kW ] | 100 | 300 | 1000 | 2800 | 3600 | 1000 | 1000 |
| Max. heat release, gas mode [ kW ] | - | - | - | - | - | 400 | 1000 |
| Max. flame length, oil mode [ mm ] | 500 | 750 | 2200 | 2600 | 3000 | 2000 | 2500 |
| Max. flame length, gas mode [ mm ] | - | - | - | - | - | 1500 | 2000 |
| Outer tube diameter [ mm ] | 50 | 70 | 90 | 135 | 160 | 90 | 135 |
| In oil mode air atomation | x | x | x | x | x | x | x |
| With spark transformer and ionisation flame monitor for intemittent operation in oil mode for continuous operation in gas mode 115V, 125V, 230V, 250V 50/60Hz, IP54/IP65 |
x | x | x | x | x | x | x |
| Power head, for zone 1 or zone 21 | x | x | x | x | |||
| Power head, for zone 2 or zone 22 | x | x | x | x | x | x | x |
|
Gas burners | |||||||||
| Heat release [ kW ] | 15 | 35 | 85 | 200 | 350 | 800 | 2000 | 3200 | 4500 |
| Flame length [ mm ] | 200 | 2500 | 300 | 400 - 500 | 600 - 1000 | 300 - 1500 | 300 - 2500 | 300 - 3000 | 300 - 3000 |
| Outer tube diameter [ mm ] | 35 | 50 | 70 | 90 | 135 | 160 | 220 | 275 | 325 |
| Turnd-down ratio | 5:1 | 10:1 | 10:1 | 10:1 | 10:1 | 10:1 | 10:1 | 10:1 | 10:1 |
| Quick change design | - | x | x | x | - | - | - | - | - |
| Burner size | P | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 |